Comprehensive Analysis of Charger Tester: The LISUN SY65240T Charger Aging Test Rack
This article explores the technical specifications, applications, and performance of the LISUN SY65240T Charger Aging Test Rack (Constant Temperature). The primary focus is on understanding the significance of the charger tester in evaluating the reliability and performance of various charging devices under controlled environmental conditions. Detailed data tables are provided to illustrate the operational parameters and test results of this charger tester, emphasizing its value in quality control and R&D for electronic chargers.
1. Introduction
The need for high-quality chargers has become critical with the growing demand for electronic devices. A charger tester, specifically the LISUN SY65240T Charger Aging Test Rack, is essential for assessing the performance and longevity of chargers. This article delves into the functionality and benefits of using the LISUN SY65240T charger tester, which provides a stable and precise environment to evaluate charger performance under aging conditions.
2. Overview of Charger Aging Test Racks
Aging test racks, commonly referred to as charger testers, are designed to simulate long-term usage conditions of chargers to ensure they meet required performance standards. The LISUN SY65240T Charger Aging Test Rack is equipped with constant temperature control, multiple testing stations, and real-time monitoring capabilities, making it an ideal choice for evaluating a wide range of charging devices.
3. Technical Specifications of LISUN SY65240T Charger Tester
The LISUN SY65240T Charger Aging Test Rack is a sophisticated charger tester designed to simulate prolonged usage of chargers under controlled conditions. Below are its technical specifications:

Parameter
Specification

Model
SY65240T

Testing Channels
40 channels per unit

Temperature Range
25°C – 70°C

Temperature Accuracy
±1°C

Power Supply
AC 220V ±10%, 50Hz/60Hz

Maximum Output Current
20A per channel

Output Voltage
0-30V adjustable

Control Method
 PLC control and software monitoring

Cooling Method
Forced air cooling

Data Storage
Supports data export and storage

Dimensions (W x D x H)
1200mm x 800mm x 1800mm

Weight
Approximately 250kg

SY65240T_Constant Temperature Charger Aging Test Rack

4. Key Features of the LISUN SY65240T Charger Tester
• Constant Temperature Control: Ensures consistent test conditions, critical for accurate aging tests.
• High Capacity: Can test up to 40 chargers simultaneously, significantly enhancing testing efficiency.
• Adjustable Voltage and Current: Allows for a wide range of charger specifications to be tested.
• Real-Time Monitoring and Data Logging: Enables precise tracking of performance parameters throughout the test.
• PLC Control: Ensures reliable automation of the testing process, minimizing human error.
5. Applications of the LISUN SY65240T Charger Tester
The LISUN SY65240T Charger Aging Test Rack is widely used in R&D labs, quality control departments, and manufacturing facilities. It is particularly valuable in industries where charger reliability is crucial, such as consumer electronics, automotive, and telecommunications.
6. Testing Procedures and Methods
The typical testing procedure for the LISUN SY65240T charger tester involves the following steps:
• Setup: Chargers are connected to the tester’s channels, and test parameters such as voltage, current, and temperature are configured.
• Aging Simulation: Chargers undergo continuous charging and discharging cycles under set conditions to simulate long-term use.
• Data Collection: Real-time data on voltage, current, temperature, and any abnormalities are collected and stored.
• Analysis: Data is analyzed to determine the charger’s performance degradation over time.
7. Performance Evaluation: Charger Tester Data Analysis
The following table summarizes the performance results obtained from a typical aging test conducted using the LISUN SY65240T charger tester.

Test Parameter
Initial Value
After 500 Hours
After 1000 Hours

Output Voltage Stability
 ±0.5%
±0.6%
±0.8%

Current Consistency
±1%
±1.2%
±1.5%

Temperature Variation
±1°C
±1.5°C
±2°C

Charging Efficiency
98%
95%
92%

Failure Rate
0%
0.50%
1%

8. Benefits of Using the LISUN SY65240T Charger Tester
Enhanced Reliability Testing: Accurately simulates long-term use to identify potential failure points.
Improved Product Quality: Early detection of performance degradation helps in refining product designs.
Cost-Effectiveness: Reduces the need for extensive field testing by providing reliable lab-based simulations.
9. Conclusion
The LISUN SY65240T Charger Aging Test Rack is an advanced charger tester that plays a critical role in ensuring charger quality and reliability. Its ability to simulate prolonged operational conditions provides valuable insights into the aging behavior of chargers, allowing manufacturers to enhance product durability and performance. This charger tester’s robust design, precise control, and comprehensive data analysis capabilities make it an indispensable tool for any industry that relies on high-performance charging solutions.
References
LISUN Group. (2024). Charger Aging Test Rack. Retrieved from LISUN Charger Aging Test Rack. https://www.lisungroup.com/news/technology-news/comprehensive-analysis-of-charger-tester-the-lisun-sy65240t-charger-aging-test-rack.html

Comments

Popular posts from this blog

What are the differences of FMVSS 302, UL94 and IEC60695 for flammability test?