What should we pay attention to during the salt spray test according to IEC and ASTM standards?

The salt spray test is an essential technique for evaluating the corrosion resistance of materials and coatings, and it is carried out in line with standards such as those established by the International Electrotechnical Commission (IEC) and the American Society for Testing and Materials (ASTM) (American Society for Testing and Materials).

When conducting a salt spray test in accordance with the requirements of the IEC and ASTM, there are various critical considerations that must be made, including the following:

  1. Test Circumstances The test conditions, which include temperature, relative humidity, and salt content, need to be regulated and kept within certain limitations, as outlined in the applicable standards. These limits may be found in the relevant standards. In addition, the calibration of the testing chamber need to be performed on a regular basis.
  2. Preparing the Specimens For the test, the specimens that are going to be examined should first be cleaned and conditioned in accordance with the applicable requirements. This will guarantee that the examination will provide accurate and reliable results.
  3. Duration of the Test The duration of the test should be stated in the applicable standards, and it should be long enough to allow for the evaluation of the specimens' resistance to corrosion.
  4. Evaluation of Results The outcomes of the test should be reviewed in accordance with the applicable standards. This evaluation should take into account the kind, degree, and location of any corrosion that was found. It is recommended that a visual examination of the specimens be carried out, and any corrosion that is seen should be quantified and documented.
  5. Documentation of Results It is important that the results of the salt spray test be recorded and published. This documentation should include the test settings, specimens, and the results. For the purpose of facilitating an objective comparison of the outcomes of various studies, this documentation must to be exhaustive and precise.
  6. Inter-laboratory Comparisons: It is important to carry out inter-laboratory comparisons so that the findings obtained from various labs can be compared and interpreted in the same manner. This may be accomplished by taking part in inter-laboratory comparison programs or by exchanging specimens and findings with other labs. Both of these methods are viable options.
  7. Re-testing: Re-testing of specimens that have failed the salt spray test may be undertaken in order to validate the findings or to assess the efficiency of corrosion prevention measures. Re-testing may be performed for any of these reasons.

In conclusion, while conducting a salt spray test in accordance with IEC and ASTM standards, it is very necessary to pay close attention to the aforementioned criteria in order to guarantee the correctness, reliability, and comparability of the findings.